TI-30X IIS Manual
Covers 1 models: 41 keys / 9 rows, expression on the upper line and result on the lower line.
Texas Instruments · 1 models · 41 keys / 9 rows · updated 2026-11-02
The two-line display is the biggest difference between the TI-30X IIS and the TI-30XA: the upper line keeps the expression you typed and the lower line gives the result. To fix a mistake you backspace directly in the expression instead of retyping from the start. The key silkscreen is all upper case, and the function layers are separated with 2nd.
Nine rows of keys, read from the top down
The TI-30X IIS uses a nine-row layout, with the number pad still centered and the operator keys in the rightmost column. The rows below are described top down and match the diagram above exactly.
| Row (top down) | Key layout | What this row handles |
|---|---|---|
| Row 1 | 2nd / DRG / DEL / Arrow keys | |
| Row 2 | LOG / PRB / °′″ | |
| Row 3 | LN / A b/c / DATA / STATVAR / CLEAR | |
| Row 4 | π / SIN / COS / TAN / ÷ | |
| Row 5 | x^ / x⁻¹ / ( / ) / × | |
| Row 6 | x² / 7 / 8 / 9 / − | |
| Row 7 | MEMVAR / 4 / 5 / 6 / + | |
| Row 8 | STO▸ / 1 / 2 / 3 / ENTER | |
| Row 9 | ON / 0 / . / (−) |
Four keys that matter
- DEL: deletes the character at the cursor, used when editing an expression.
- CLEAR: clears the current line; pressing it repeatedly usually takes you back to the state you had on entering the calculation.
- ENTER: runs the calculation, the equivalent of = on a Casio.
- MEMVAR: opens the memory-variable menu, used with STO▸ to store and recall intermediate results.
- PRB and DATA live in the 2nd layer: the entry points for permutations and combinations and for statistics data, not printed on the main key face.
2nd-layer silkscreen labels
| Key | SHIFT layer | ALPHA layer |
|---|---|---|
| DRG | SCI/ENG | — |
| DEL | INS | — |
| LOG | 10ˣ | — |
| PRB | F↔D | — |
| °′″ | R↔P | — |
| LN | eˣ | — |
| A b/c | Aᵇ/ᶜ↔d/e | — |
| DATA | STAT | — |
| STATVAR | EXIT STAT | — |
| π | HYP | — |
| SIN | SIN⁻¹ | — |
| COS | COS⁻¹ | — |
| TAN | TAN⁻¹ | — |
| ÷ | K | — |
| x^ | ˣ√ | — |
| x⁻¹ | EE | — |
| ( | % | — |
| ) | ; | — |
| x² | √ | — |
| MEMVAR | CLRVAR | — |
| STO▸ | RCL | — |
| ON | OFF | — |
| 0 | RESET | — |
| . | FIX | — |
| (−) | ANS | — |
Matching the angle unit to the problem
The DRG key switches the angle unit and the top of the screen shows the DEG / RAD / GRAD indicator. Check that indicator before any trigonometry: the same sin(30) is 0.5 in DEG and −0.988 in RAD. Statistics and fraction problems are not affected.
Statistics: from entry to read-out
Statistics on the IIS is a two-key process: DATA for entering and 2nd + DATA for reading out. The step that trips people up is believing the data is in when it is not. Every value needs a confirmation press to push the cursor down to the next row, otherwise the number stays in the editing buffer and the statistics commands cannot see it.
- Press DATA to enter data entry, type each value and confirm it so the cursor moves down one row at a time.
- While entering, use the direction keys to go back up and change a row, then continue downward.
- Press 2nd + DATA for the statistics read-out and use the direction keys to switch among n, Σx, Σx², x̄, σx and sx.
- When you are done reading, first check that n equals the number of values you entered, then copy the results.
The PRB menu: factorials, permutations, combinations and random numbers
PRB is printed on the key face, but it is a 2nd-layer function. Its menu collects four groups: factorial, nPr, nCr and random numbers, which you use over and over in probability problems.
- The factorial works only on non-negative integers; entering 3.5 or a negative number errors out immediately.
- For permutations and combinations the argument order is n first and r second; reversing them changes everything: 5P2 = 20, while 2P5 is meaningless.
- Random numbers differ on every run and cannot be reproduced; if you need to repeat an experiment, write in a fixed data set yourself.
Fraction <-> decimal conversion
Fractions are entered with A b/c: whole number, numerator and denominator each get one press, and mixed numbers and proper fractions follow the same path. F<->D is printed above the PRB key, in the 2nd layer, and switches the display between fraction and decimal.
MEMVAR and STO▸: several intermediate results
- STO▸ followed by a variable name stores the current value; MEMVAR opens the variable menu, where you can recall a value or zero it out.
- There are only a few variables, enough for a three- or four-step problem, but not enough to use as scratch paper.
- CLRVAR is printed above MEMVAR, in the 2nd layer, and clears every variable at once; make sure no result you still need is in there before you clear.
Trade-offs against the MultiView
| Aspect | TI-30X IIS | TI-30XS MultiView |
|---|---|---|
| Display | Two lines (expression + result) | Four lines, with history you can scroll back through |
| Typesetting | Plain characters | MathPrint mathematical typesetting |
| Fraction key | A b/c | n/d and fraction templates |
| Table feature | No dedicated table key | Has a table key |
| Learning cost | Low, and there are many tutorials | Slightly higher, with a denser key layout |
A simple rule: if your problems are mostly one evaluation at a time and you need to stay in sync with the teacher's demo, the IIS is steadier; if they are multi-step derivations where you go back and edit the previous line, the four-line display of the MultiView saves a lot of retyping. The two have no generation gap in computing power.
Errors and troubleshooting
| What the screen says | Usual cause | What to do |
|---|---|---|
| Syntax ERROR | Unclosed parentheses, two operators in a row, a function missing its argument | Use the direction keys to move the cursor to the bad spot and fix it one character at a time with DEL |
| Overflow / odd result | The exponent is outside the representable range, or chained powers go too deep | Split the calculation into steps; enter scientific notation with EE |
| Statistics read-out is empty | The data was never really entered, or the frequency column is set to 0 | Go back to DATA and check the list length and the frequencies |
Battery, contrast and reset
- Dim screen: adjust the contrast with 2ND + direction keys up or down, and replace the battery only if it still looks grey at the limit.
- Power: solar assist plus a button-cell battery. A readable screen in bright light does not mean the battery has charge, so check the marking on the back cover before an exam.
- Reset: 2nd + CLEAR wipes everything and the screen asks you to confirm; if you only want to clear the current line, CLEAR is enough.
- Cleaning and storage: wipe with a dry cloth and never spray alcohol directly on it; take the battery out for long storage to prevent leakage.
Models in this series
Related operations for this series
- Switch the angle unit (DEG / RAD / GRA) Get the angle unit wrong and sin(30) comes out wrong. Here is the complete key path across four generations of key layout.
- Factory reset and selective clearing A reset wipes variables, programs, and settings - tell the All / Memory / Setup scopes apart before you press anything.
- Converting between fractions and decimals Toggling the display does not change the stored value; whether a conversion is exact depends on the denominator.
- Entering and displaying scientific notation Use the EE / ×10ˣ key for exponents instead of typing ×10^ by hand.
- Percentages and increases or decreases of a number Multiply then divide, or use the percent key directly; both paths should agree, which makes them good cross-checks.
- Logarithms in any base With a log▭ template key, just fill in the base; without one, use the change-of-base formula in two steps.
Frequently asked questions
These questions apply to this series. For the general ones, see all FAQ entries.
Why doesn't sin(30) come out to 0.5?
The model's current angle unit isn't DEG. On Casio ES/EX use SHIFT + SETUP or the menu to switch to Degree; on CW press SETTINGS to reach the angle unit; on TI press DRG or the mode key to switch. The D / R / G marker at the top of the screen is the current unit.
How do I restore factory settings?
Casio: open the setup menu and find Reset (on ES/EX it's the Reset after SHIFT + MODE, on CW it's inside SETTINGS), choose All and confirm; this clears memory, variables, and settings. TI: press 2ND + + (MEM) to enter the MEM menu and choose Reset, or remove the battery and wait a few seconds. Before resetting, write down any formulas and data you need to keep.
What if I only want to clear variables, not reset all settings?
The Casio Reset menu usually has three levels: Setup Data, Memory, and All. Choosing Memory clears only the variables and Ans while keeping the angle unit and display settings. On TI-84 the MEM menu reached with 2ND + + has separate All, Defaults, and Vars options; choose Vars.
What does Math ERROR mean?
The operation is mathematically undefined or out of range: division by 0, an even root of a negative number, tan(90°), or an overly large factorial argument all trigger it. Press AC or CLEAR to clear the line, then check the angle unit and order of operations. It doesn't mean the device is broken.
How do I locate a Syntax ERROR?
It's usually an unclosed parenthesis, two operators in a row, or a function missing an argument. On Casio use the arrow keys to move the cursor to the error and fix it; on TI-84 press 2 (Goto) to jump to the error location. Once fixed you don't need to retype the whole line.
The result is always a fraction; how do I show it as a decimal?
On Casio press S⇔D (FORMAT on CW) to toggle between fraction and decimal; you can also change the result display to LineIO / Decimal in the settings. On TI press 2ND + ENTER (F◂▸D) or just enter the value with a decimal point. Toggling only changes the display, not the stored value.
How do I turn 0.375 into 3/8?
Enter 0.375 and press S⇔D (FORMAT on CW, 2ND + ENTER on TI) to try converting it to a fraction. If it won't convert, the decimal can't be represented within the current denominator precision (for example an approximation of a repeating decimal that was truncated).
Why are the negative sign and the minus sign on two separate keys?