FAQ

Frequently asked questions

Grouped by topic, 120 questions in all. Where a step differs by series, the question and answer name it — because MODE, MENU, and HOME are reached differently across generations. Each series manual page also lists just the entries that apply to that series.

Angle Unit

Why doesn't sin(30) come out to 0.5?

The model's current angle unit isn't DEG. On Casio ES/EX use SHIFT + SETUP or the menu to switch to Degree; on CW press SETTINGS to reach the angle unit; on TI press DRG or the mode key to switch. The D / R / G marker at the top of the screen is the current unit.

Angle Unit

Reset

How do I restore factory settings?

Casio: open the setup menu and find Reset (on ES/EX it's the Reset after SHIFT + MODE, on CW it's inside SETTINGS), choose All and confirm; this clears memory, variables, and settings. TI: press 2ND + + (MEM) to enter the MEM menu and choose Reset, or remove the battery and wait a few seconds. Before resetting, write down any formulas and data you need to keep.

Reset

What if I only want to clear variables, not reset all settings?

The Casio Reset menu usually has three levels: Setup Data, Memory, and All. Choosing Memory clears only the variables and Ans while keeping the angle unit and display settings. On TI-84 the MEM menu reached with 2ND + + has separate All, Defaults, and Vars options; choose Vars.

Reset

Errors

What does Math ERROR mean?

The operation is mathematically undefined or out of range: division by 0, an even root of a negative number, tan(90°), or an overly large factorial argument all trigger it. Press AC or CLEAR to clear the line, then check the angle unit and order of operations. It doesn't mean the device is broken.

Errors

How do I locate a Syntax ERROR?

It's usually an unclosed parenthesis, two operators in a row, or a function missing an argument. On Casio use the arrow keys to move the cursor to the error and fix it; on TI-84 press 2 (Goto) to jump to the error location. Once fixed you don't need to retype the whole line.

Errors

Is Stack ERROR an out-of-memory problem?

It's a nesting or numeric stack overflow, not insufficient storage. It's common with deeply nested parentheses, repeated power operations, or very large factorials. Split the calculation into two steps and carry the intermediate result with Ans.

Errors

Fractions and Decimals

The result is always a fraction; how do I show it as a decimal?

On Casio press S⇔D (FORMAT on CW) to toggle between fraction and decimal; you can also change the result display to LineIO / Decimal in the settings. On TI press 2ND + ENTER (F◂▸D) or just enter the value with a decimal point. Toggling only changes the display, not the stored value.

Fractions and Decimals

How do I turn 0.375 into 3/8?

Enter 0.375 and press S⇔D (FORMAT on CW, 2ND + ENTER on TI) to try converting it to a fraction. If it won't convert, the decimal can't be represented within the current denominator precision (for example an approximation of a repeating decimal that was truncated).

Fractions and Decimals

Input

Why are the negative sign and the minus sign on two separate keys?

The minus sign is a binary operator; the negative sign (−) is a number sign. In 5 − (−3) they must be kept separate, otherwise the device reads two minuses in a row as a syntax error. On TI models the two keys are (−) and −.

Input

How do I enter degrees, minutes, and seconds?

On Casio use the °′″ key to cycle through degrees, minutes, and seconds; for 30°15′20″ press the numbers and the key in turn. During calculation it can convert to and from decimal degrees, and trig functions interpret it by the current angle unit. On TI use the degrees-minutes-seconds symbol in the 2ND + APPS (ANGLE) menu.

Input

With a function key, do you press the function first or the number first?

Both Casio and TI press the function first and then enter the argument; an open parenthesis appears on the screen and you add the closing parenthesis yourself. A few template keys (like fraction and radical) build the structure directly, with the cursor landing inside it.

Input

The cursor eats the characters after it while I type?

The model is in overwrite state of the insert/overwrite mode. Press 2ND + DEL (INS) or the equivalent combination to switch back to insert mode. On TI-84 the INS label is printed above the DEL key.

Input

How do I enter 30°15′20″?

Enter 30, press °′″, enter 15, press °′″, enter 20, then press °′″ once more to finish. On CW the °′″ label is above the + key and needs SHIFT first. On models without the key, compute 30 + 15÷60 + 20÷3600 by hand for an equivalent result.

Input

Can degrees-minutes-seconds convert directly to decimal degrees?

Yes. After the last °′″ press, the result is usually already given in the current display format; if it's still in degrees-minutes-seconds form, press S⇔D (FORMAT on CW) to toggle the display. Converting the other way generally requires the inverse operation or the matching item in the menu.

Input

How do I enter a negative degrees-minutes-seconds value?

Put the negative sign in front of the whole angle, not just on the degrees. −30°15′ means negative 30 degrees 15 minutes; if you enter −30 degrees and then add 15 minutes, it equals −29°45′, with both the direction and the value wrong.

Input

Can the device do unit conversions?

Some models have built-in conversion (CONV) and constants (CONST), reached from the SHIFT layer on the key face or from a menu. The available conversions vary by model, so when solving, first check whether the unit is in the list; if it isn't, compute the conversion factor by hand—it's faster than hunting through the menu.

Input

Scientific Notation

How do I enter a number like 6.02×10²³?

On Casio use the ×10ˣ key for the exponent part and just enter 6.02 ×10ˣ 23. On the TI-30 series press EE; on TI-84 use 2ND + EE (the EE key itself). Don't type ×10^ by hand—the precision and display format differ.

Scientific Notation

What does engineering notation (ENG) do?

It aligns the result to powers of 10³, which makes converting between engineering units like k, M, and μ easier. On Casio press the ENG key to cycle through and SHIFT + ENG to go in reverse. It only changes the display, not the value.

Scientific Notation

What's the difference between ENG and SCI?

SCI is scientific notation with a fixed number of significant digits, where the exponent can be any integer; ENG forces the exponent to a multiple of 3 (10³, 10⁶, 10⁹), which pairs well with prefixes like k, M, and μ. Both change only the display, not the value.

Scientific Notation

Display Settings

Results only show two or three decimals; how do I get more digits?

In the settings, change the display mode from Fix to Norm (Normal). Fix sets a fixed number of decimal places; Norm sets the number of significant digits. On Casio it's under Number Format in SETUP, on CW it's in SETTINGS; on TI it's on the second page of the mode menu.

Display Settings

What if the screen is dim or hard to read?

On dot-matrix display models the contrast is adjustable: on Casio usually press SHIFT + up/down arrow (or press MODE repeatedly to reach the contrast screen), on TI use 2ND + arrow keys. Seven-segment models (like TI-30XA) have no contrast menu. If the display still looks faint at maximum, it's usually low battery voltage—replace the battery and readjust.

Display Settings

Why is my result's last digit different from the textbook's?

The calculator's internal precision is higher than its display precision, and the display rounds, so the last digit can be off by 1. To check, increase the number of displayed digits or output as a fraction; don't back-calculate intermediate results from the displayed value.

Display Settings

After maxing the contrast, there's a ghost image?

Too high a contrast darkens pixels that shouldn't be lit, which looks like a ghost image. Turn it down two or three steps until the characters are sharp and the background is clean. It's not a broken screen, and you don't need a new battery.

Display Settings

Power

Pressing ON does nothing; is it broken?

First replace the battery, then check whether long disuse caused leakage that corroded the contacts. Models with a solar panel may work briefly in strong light; that means the battery is drained, not that the whole device is damaged. If there's still no display after a new battery, consider a reset or sending it in for repair.

Power

Can the solar panel fully replace the battery?

No. Solar power is only supplemental; in dim conditions it still relies on the battery. When the battery is drained, strong light may power the display but calculations become unreliable. For exams, make sure the battery has charge and don't count on indoor lighting.

Power

What battery should I use?

Scientific calculators mostly use button cells (commonly LR44 / CR2032 types); graphing calculators use AA/AAA batteries or a dedicated rechargeable pack. Before opening the back cover, confirm the battery type printed on the device—different production batches can differ, so don't buy by guesswork.

Power

It powers off on its own when left idle; is that normal?

Yes, it's normal. After a few minutes of no activity it powers off to save battery; press ON to resume, and your previous expression is usually still there. Auto power-off isn't a fault and doesn't mean the battery has a problem.

Power

How do I tell the positive and negative sides when changing the battery?

The battery compartment usually has + / − markings; on a button cell the flat side is positive and the raised side is negative—place it per the compartment markings. Putting it in backwards generally won't burn out the device but it won't power on; after a change, do a reset once to clear leftover old settings.

Power

Is a solar model fine under exam-room lighting?

Don't rely on it. Solar power is only supplemental, and exam-room lighting usually isn't enough to drive calculations; when the battery is drained you get the "lights up in bright light but keys don't respond" behavior. Before the exam put in a new battery per the marking on the back cover—don't gamble on the room lights.

Power

Faults

A key doesn't respond when I press it?

First reset to rule out a software-level problem; if that doesn't help, it's usually dirty or aged conductive rubber under the keycap. Don't open the device yourself (it breaks the anti-static protection and the warranty); you can brush dust out of the key gaps with a soft brush first, then send it in for repair.

Faults

There's a dark spot on the screen that won't wipe off?

First tell a surface smudge from an LCD problem: if a dry cloth won't remove it, it's still visible at an angle, and its position is fixed, it's most likely a pressed or aged liquid-crystal layer. Avoid further pressure; if the dark spot spreads, send it in for repair. A surface smudge can be wiped gently with a slightly damp lint-free cloth.

Faults

A key feels stiff and springs back slowly?

It's usually aged conductive rubber under the keycap or something that got into it. Don't pry the keycap off with a sharp object (it easily tears the rubber); you can first clear the key gap with a soft brush, and if that doesn't help, send it in for repair. Parts for older models are hard to find, so before a repair confirm whether it's worth it.

Faults

After it gets wet, can I still turn it on?

Don't power it on right away. First cut power (remove the battery), hold the device face-down and tap it gently to drain the liquid, and let it air-dry at room temperature for at least 24 hours—don't use a hair dryer to heat it. Put the battery back and test it only once it's fully dry; powering on immediately after liquid gets in most often causes corrosion and a short.

Faults

Exams

Can I bring this calculator into the exam?

It depends on the exam organizer's current rules, which can change from year to year. Graphing calculators (TI-84, Nspire) are restricted in most standardized tests or must have their programs cleared; scientific calculators are usually allowed but formulas on the slide case are forbidden. Follow the official candidate instructions for that year; this site makes no promise of approval.

Exams

How do I turn on the Press-to-Test or exam mode an exam requires?

TI models have Press-to-Test: with the device off, hold the specified key combination and then power it on (commonly 2ND + ON or DOC + ENTER, depending on the model); this temporarily disables programs and some features, and a reboot restores them. Casio has no mode by that name and relies on memory being cleared under proctor supervision.

Exams

How do I exit Press-to-Test?

Usually just power the device back on to exit; some models require connecting to a computer or using a specific combination to clear it. After exiting, programs, lists, and settings are restored as they were—it's a temporary lockout, not a deletion. After the exam, confirm you've exited before powering off for storage.

Exams

After entering exam mode, are my own programs still there?

Yes. Press-to-Test only hides programs and some features temporarily and restores them as-is when you exit. But if the proctor requires "deleting programs," that's a different matter—once deleted, they're gone. Confirm the requirement before you do anything.

Exams

Does Casio have an exam mode?

The scientific calculator line has no Press-to-Test-style mode. Proctors usually require memory and programs to be cleared on site (a reset or item-by-item deletion); there's no one-key "enter exam mode" switch. Don't apply TI's key combinations to a Casio.

Exams

Modes

How do I enter the Statistics / Equation / Matrix modes?

On Casio ES press MODE and pick a mode with a number; on EX press MENU and pick an icon; on CW press HOME and pick an icon. On TI-84 use STAT to enter Statistics, 2ND + x⁻¹ for MATRX, and find the solver under MATH. When you can't find a feature, search the menu/CATALOG rather than guessing key presses.

Modes

Can't find a MODE key on CW?

CW uses HOME to enter feature selection and SETTINGS to change settings; these two replace the MODE and SHIFT + MODE of older models. Press HOME, use the arrow keys to pick an icon, then press OK or EXE to enter.

Modes

How do I change the angle unit on EX?

Press SHIFT + MENU to open SETUP and choose Degree / Radian / Gradian under Angle Unit. EX has no MODE key, so the SHIFT + MODE from older tutorials doesn't apply to this device.

Modes

On Nspire I ended up in an unfamiliar screen by pressing around?

Press esc to step back out, or press doc to return to the documents menu. For a quick one-off calculation, press ON to open a scratchpad—no need to create a new document; scratchpad contents aren't kept after power-off.

Modes

Are the F1–F5 keys on TI-85 fixed?

No. The F keys run whichever function is shown at the bottom of the screen at that moment, so the functions change when the screen changes. When you can't find a feature, page through MORE, or use CUSTOM to assign common commands to the F keys.

Modes

Calculation Efficiency

What's Ans actually useful for?

Ans stores the previous result and can feed directly into the next calculation, for example after getting 2.5 press ×4 to get 10. It's also handy for step-by-step calculations that avoid deeply nested parentheses. Ans is cleared after a reset or power-off.

Calculation Efficiency

How do I repeatedly calculate several similar data sets?

Write the calculation as an expression with variables, change the values with STO, and rerun it; or use Ans to carry the previous step's result. On TI-84 you can store the formula in y= and evaluate it in bulk in the table, which is far faster than retyping each time.

Calculation Efficiency

Variables

How do I store an intermediate result to reuse it?

On Casio press STO followed by a variable name (A–F, M, etc.), then press the variable key to recall it; on TI-84 press STO▸ then ALPHA + a letter; on TI-30X IIS use STO▸ with the MEMVAR menu. Variables are cleared after a reset.

Variables

Statistics

How do I find the mean and standard deviation of a data set?

Casio: enter STAT mode, input univariate data, choose 1-VAR, then read x̄ and σx. TI-30XS: enter data with the data key and view results with 2nd + data. TI-84: use STAT → EDIT to fill L1, then STAT → CALC → 1-Var Stats.

Statistics

Statistics finishes but says no data or the result is empty?

Usually the data wasn't actually written into the list (you finished entering it without pressing confirm), or the frequency column was accidentally set to 0. Check that the list lengths match, then rerun the statistics command. On TI-84 you can clear the lists first with ClrList under 2ND + STAT and start over.

Statistics

After a regression I see r and r²; which should I use?

r is the correlation coefficient (−1 to 1), measuring the direction and strength of a linear relationship; r² is the coefficient of determination, the proportion the model can explain. Use r when the problem asks about correlation and r² when it asks about goodness of fit. An r near 0 doesn't mean there's no relationship, only that there's no linear relationship.

Statistics

Can I use the regression equation to predict a new value?

Yes, but watch out for extrapolation risk. The a and b the device gives are reliable only within the sample range you entered; beyond it, prediction error grows rapidly. In your answer, state clearly that you're estimating from the fitted line, and keep the original data.

Statistics

n doesn't match the number of values I entered?

Most likely you missed the confirm key: each value needs a confirm press to move the cursor to the next line, otherwise the data stays only in the edit buffer. It could also be leftover data from the previous set. Clear the list first, then enter each value and verify n.

Statistics

How do I clear all the statistics lists at once on TI-84?

Press 2ND + + to enter the MEM menu, choose ClrAllLists, and press 2 to select Yes on the confirmation. Note this clears only the lists, not programs or settings; to clear programs use Mem Mgmt/Del, and to restore defaults use Reset.

Statistics

Equations

Can it solve a quadratic equation directly?

Casio models with an equation mode (like the 991 series) can select Polynomial in EQN and enter the coefficients to find the roots. Models without an equation mode can only use the quadratic formula by hand, and the result comes out as a fraction or decimal. Graphing calculators can use the intersection/zero features.

Equations

Why does SOLVE give only one root?

SOLVE is a numerical iteration that stops once it finds one solution. For a quadratic with two roots, change the initial value and solve again, and you'll usually get the other root. To get all roots at once, use the equation mode (Polynomial) instead of SOLVE.

Equations

SOLVE asks for an initial value; can I just put in anything?

No, not randomly. The initial value decides which root it converges to and can also cause non-convergence. When solving, first estimate an approximate value from the function's monotonicity or a numeric table, then enter it as the initial value for faster, more reliable convergence.

Equations

How do I tell whether a SOLVE result is trustworthy?

Substitute the solution back into the original expression and see whether the result is close to 0. If the residual is significant (0.7 instead of 0.0001, for example), it didn't truly converge: change the initial value, check whether the equation's parentheses are wrong, or switch to an analytic method.

Equations

Complex

How do I calculate (3+4i)×(1−2i)?

First switch the model into Complex mode (CMPLX / Complex on Casio, or choose Complex in HOME on CW), then enter the imaginary part with the i key. The display can be toggled to polar form. Basic models have no Complex mode and require expanding by hand.

Complex

Why is the result real after I enter i?

The model isn't in Complex mode. In normal calculation mode, i may be treated as a variable (with value 0), so the imaginary part vanishes. First press MODE / MENU / HOME to enter CMPLX or Complex mode, then enter i.

Complex

How do I convert a complex result to polar form?

Use the complex format toggle in the settings (a+bi ↔ r∠θ), or a Pol conversion. Note that toggling changes only the display, not the value; before copying the answer, confirm which form the problem wants, and especially state whether the angle is in DEG or RAD.

Complex

The argument differs from the answer by 360°?

The argument has a principal-value range (commonly −180°~180° or 0°~360°); the device gives the principal value, while the answer may be written on a different cycle. When they differ by an integer multiple of 360°, the two are mathematically equivalent—just rewrite it in the form the problem asks for.

Complex

Base-N

How do I convert between binary and hexadecimal?

On Casio enter BASE-N mode and use the DEC / HEX / BIN / OCT keys to switch the input/output base; negative numbers follow two's-complement rules. On TI-84 use 2ND plus a semicolon-style combination to enter base conversion, or use the DEC / HEX prefix functions.

Base-N

Why can't I enter decimals in base mode?

BASE-N mode handles only integers, and decimal points and fractions are rejected. For a base conversion that involves a decimal, compute the integer part and the fractional part separately (multiply the fractional part by the base and take the integer), or return to normal calculation mode and convert with division.

Base-N

Why does −1 show as a string of F's in hexadecimal?

This is two's-complement representation. A negative integer is stored as its two's complement within the machine word length, so −1 is all 1s and displays as FFFF.... Don't assume a string of F's is an overflow—switch to decimal to check whether it's the negative number you entered.

Base-N

Matrix

How do I enter a matrix and find its determinant?

On Casio enter MATRIX mode, first define the dimension of MatA and enter each cell, then use det(MatA) for the determinant. On TI-84 press 2ND + x⁻¹ to enter MATRX, set the dimension in EDIT, then choose det in the matrix menu. A dimension mismatch causes an error.

Matrix

Graphing

The screen is blank after graphing?

It's almost always the window range: the function has no value in that interval, or the range is far off the function's scale. Use ZStandard (in the ZOOM menu) to restore the default window, then fine-tune Xmin/Xmax and Ymin/Ymax to the actual scale.

Graphing

How do I graph two curves at once to see their intersection?

Enter Y1 and Y2 separately in the y= editor and press GRAPH to plot both. To find the intersection, open the CALC menu with 2ND + TRACE, choose intersect, then confirm the two curves and the initial guess position in turn. Color-screen models distinguish the curves with different colors.

Graphing

How do I find a zero on the graph?

TI-84: open CALC with 2ND + TRACE, choose zero, use the arrow keys to place the cursor to the left of the root and confirm, then to the right and confirm, and give an initial guess. A graphing calculator won't find all zeros automatically, so with multiple solutions work through them one interval at a time.

Graphing

How do I read a maximum or minimum point?

In the same CALC menu opened with 2ND + TRACE, choose maximum or minimum, and set the left and right bounds and the guess position. What you read out is only a local extremum within the current window—don't treat it as the global maximum or minimum.

Graphing

Can't graph a polar equation?

The graphing mode in MODE is still on Func. First switch to Polar (or Param), then return to the y= editor to enter the r= expression. If the mode isn't switched, what you enter is treated as y=f(x), so of course the graph comes out wrong.

Graphing

Table

How do I generate a numeric table for a function?

On Casio enter TABLE mode, input f(x), set the start value, end value, and step, then confirm. On TI-30XS use the table key; on TI-84 use 2ND + GRAPH to enter TABLE and set the step with TBLSET.

Table

Why did the numeric table skip the root I was looking for?

The step is too large. First scan the suspicious interval with a smaller step; once you see the sign change from positive to negative, narrow the Start/End range and reduce Step to locate it precisely. A step of 0 or a negative value is rejected by the device.

Table

The numeric table comes up empty after generating?

A common cause is that the function wasn't actually written into f(x) (entered but not confirmed), or Start is greater than End. Check whether the function is empty and whether the interval is valid; on TI-84 also confirm the independent/dependent setting for TABLE is correct.

Table

Data

Programs and variables are gone after changing the battery?

If power is lost for too long during a battery change, volatile memory is wiped. The correct approach is to keep a second power source connected during the change (some models support this) or back up beforehand. TI-84 can export via LINK or computer software; Nspire saves as document files.

Data

TI-84 says memory is full; what do I do?

Use 2ND + + to enter the MEM menu and check RAM and Archive usage, then delete unused programs, images, and lists. You can also archive programs to free up RAM. If Archive space is also full, you'll need to delete old archived items.

Data

Care

Can I wipe the keyboard with alcohol?

You can use a slightly damp lint-free cloth with a small amount of neutral cleaner, and avoid letting alcohol seep into the key gaps or the screen coating. Wipe the screen dry with a microfiber cloth; don't use cleaners containing ammonia or abrasives.

Care

Do scratches on the screen affect reading it?

Shallow scratches are usually only on the protective layer and don't affect the display; deep scratches cause localized glare that's obvious when you look at an angle. Consider applying a dedicated screen protector before exams, and avoid pressing the screen with hard objects.

Care

Can I bring the hard case with formulas printed on it into the exam?

Most exams explicitly forbid bringing a case printed with formulas or formulas stuck onto the device; follow the candidate instructions for details. The case itself protects the screen and keys, so you can keep it for normal use and deal with it per the rules before entering the exam.

Care

Percentages and Ratios

CW has no % key; how do I do percentages?

Just divide by 100: 15% of 600 is 600 × 15 ÷ 100 = 90. CW moved the % label off the key face, but division is always there, so the path is actually shorter. Only the ES/EX line has a % silkscreen label: on ES it's above the ( key, on EX above the ) key, and both need SHIFT first.

Percentages and Ratios

Why can't I just use ×15% for a 15% price increase?

×15% gives you 15% of the original price, not the increased price. A 15% increase means multiplying by 1.15 (100% + 15%); a 15% decrease means multiplying by 0.85. Getting the base wrong is the most common mistake in percentage problems; after calculating, check that the result should be larger than the original price.

Percentages and Ratios

How do I find what percent one number is of another?

Use part ÷ whole × 100. For example 90 ÷ 600 × 100 = 15, meaning 90 is 15% of 600. Some models add the ×100 automatically when you press the % key, giving the same result, but for homework you should write out the intermediate expression clearly.

Percentages and Ratios

If I take 20% off and then 10% off, is that the same as 30% off?

No. 0.8 × 0.9 = 0.72, which is 28% off overall (the price is 72% of the original). Successive percentages multiply instead of adding, and that's where discount and growth problems get mixed up most easily.

Percentages and Ratios

Logarithms and Radicals

What's the difference between log and ln?

log is the common logarithm with base 10, and ln is the natural logarithm with base e. When solving a problem, first confirm which one it asks for; many errors where "the result is off by a constant factor" come from pressing the wrong one of these two keys. A logarithm of any base needs a template key or the change-of-base formula.

Logarithms and Radicals

In the log▭ template, do you fill in the base or the argument first?

Fill in the base first, then the argument. For log₂8 you enter 2 then 8, getting 3; reversing the order computes log₈2 = 0.333. If you fill it in wrong, you don't need to clear the screen—use the arrow keys to go back into the box and change it.

Logarithms and Radicals

Getting Math ERROR when calculating log(−5) means it's broken?

No. Within the real numbers a logarithm is defined only for positive values, and 0 has no logarithm either. If the problem genuinely involves a negative number, it should be handled in Complex mode, or the problem itself has a domain restriction you need to consider first.

Logarithms and Radicals

Why does ∛−8 sometimes give a complex number?

Most models' cube-root template handles negatives correctly (giving −2), but with a power form like x^(1/3) the device may take the complex branch. If you get a complex result, use the ∛ template key instead, or compute ∛8 = 2 first and then add the negative sign.

Logarithms and Radicals

How do I enter a fifth root or an nth root?

Models with the ˣ√▭ template let you enter the index and the radicand directly; without it, use x^(1/n)—for the fifth root of 32 enter 32 ^ ( 1 ÷ 5 ). The division in the exponent must be in parentheses, or it computes as 32^1÷5 = 6.4.

Logarithms and Radicals

Probability and Combinatorics

What's the actual difference between nPr and nCr?

The difference is whether order counts as distinct. 10P3 = 720 means taking 3 and considering the arrangement order; 10C3 = 120 means you only care which 3 are chosen. Rule of thumb: a combination count is always less than or equal to its permutation count—compare after calculating to see if you pressed the wrong key.

Probability and Combinatorics

For 10P3, do you press 10 first or 3 first?

Enter the total 10 first, then press the nPr key, then enter the selection count 3. Reversing the order becomes 3P10, and the device usually errors out rather than returning 0—the error itself is a useful hint.

Probability and Combinatorics

Calculating 30! errors out or shows an exponential form?

Factorials grow extremely fast; past the display digits the device switches to scientific notation, and beyond that it overflows. For permutations and combinations, don't work around it by dividing factorials—use the nPr/nCr keys directly, which simplify internally first and are less likely to overflow.

Probability and Combinatorics

Why does 0! equal 1?

It's a definition: arranging 0 objects in a row can be done only one way (arranging nothing). The device returning 1 for 0! is correct, not a bug. Negative integers and decimals have no ordinary factorial definition, so entering them errors.

Probability and Combinatorics

Random numbers differ every time; can they be fixed?

Ordinary scientific calculators don't offer a seed setting; after power-off or reset they use a different sequence, so results can't be reproduced. For an experiment that needs reproduction, write down each number as it's generated, or use the random number table given in the problem.

Probability and Combinatorics

How do I generate a random integer from 1 to 6?

Use a RanInt-type function to set the lower and upper bounds. On EX it's printed above the ×10ˣ key; enter 1 and 6, and each press of = generates a new value. Models with only Ran# (a 0–1 decimal) can build it by hand with INT(6×Ran#)+1.

Probability and Combinatorics

Web Calculator

Does the online calculator send my expression to a server?

No. The expression is parsed and evaluated inside the browser tab, and the answer appears without a round trip - there is no calculation endpoint to call. History, variables and notebooks are written to this browser's own storage, so a cleared browser means a clean slate.

Web Calculator

Why does nothing happen when I type a letter on my keyboard?

The physical keyboard is mapped only to keys with one unambiguous meaning: digits, + - * / ^ ( ) % . and , , Enter or = for equals, Esc for AC, Backspace for DEL, and the arrow keys on models that have them. The SHIFT and ALPHA layers need the on-screen Shift key first, because your keyboard's own Shift would otherwise steal every symbol - and Cmd, Ctrl and Alt are left to the browser.

Web Calculator

Is the web calculator as strict about errors as a real device?

Yes, deliberately. The screen keeps fourteen digits, so 1/3 reads 0.33333333333333, and a factorial above 69 is answered with Math ERROR instead of an infinity. sin(45) depends on the angle unit: in DEG it is 0.70710678118655, while typing sin(45 degrees) is a Math ERROR rather than a rounding problem.

Web Calculator

Can the web calculator be set to Fix, Sci or Norm like a real device?

It cannot, and there is nowhere to set it. There is one display: results come out to fourteen significant digits, with no fixed-decimal (Fix) mode and no significant-figures scientific (Sci) mode; the settings sheet only holds the angle unit, the model, the parsing rules and so on. The FIX, SCI and Rnd legends on the SHIFT layer are copied from the hardware and nothing is bound to them here - press SHIFT and then that key and you get the key's own character (SHIFT + 0 gives 0, SHIFT + . gives a decimal point) with the digit count unchanged. Round to the places you need yourself.

Web Calculator

Where is the Calculate button on the graphing calculator?

There isn't one. The canvas is live and every keystroke replots, which is why a half-typed expression is kept with a note that it isn't finished yet instead of being thrown away. With an empty list the page offers five examples, including the implicit circle x^2 + y^2 = 9.

Web Calculator

Can the graphing calculator draw polar or parametric curves?

Not that one. It takes y = f(x), an equation in x and y, or a table of points. For a curve given as (x(t), y(t)), or for a surface, use the 3D grapher, which accepts parametric curves, parametric surfaces, implicit surfaces, vector fields and single points.

Web Calculator

Why does sin(x) only complete a cycle near x = 6.28?

The grapher opens in radians, so one period is 2pi. ANGLE UNIT in the ⋯ menu switches between Radians, Degrees and Gradians; in degrees the same curve closes its first cycle at x = 360. It is the same angle setting the calculator keyboard uses and the browser remembers it, so switching here switches sin/cos on the calculator too.

Web Calculator

The 3D page shows a sentence where the picture should be?

That page renders with WebGL, and when the browser or the graphics driver cannot provide a context it says so plainly instead of leaving an empty box. A locked-down browser, a remote desktop or an old virtual machine is the usual cause. The flat grapher needs nothing special.

Web Calculator

How do I limit where a 3D curve is drawn?

Write the range as an inequality in braces after the expression: (3cos(t), 3sin(t), t/2) {0 < t < 6pi} draws a helix over six radians of t. AXIS RANGES does the same job for x, y and z, and Reset ranges returns to the bounds the engine computed.

Web Calculator

Why did the same integral give 2 once and 0.0861 another time?

Trigonometry follows the angle unit, and the two entry points start differently: the standalone integral page opens in radians, where the integral of sin(x) from 0 to pi is 2, while the tab inside the workbench starts in degrees, where the same input reads 0.0861069700413. Set the unit before comparing against a textbook.

Web Calculator

I asked for 200 Riemann intervals but only see about eighty rectangles?

The count and the drawing are separate. Intervals are accepted between 1 and 500 and the sum is computed with the number you typed, but only the first 80 rectangles are drawn so the plot stays readable. Midpoint is the default rule, and the rectangles must be switched on under Show rectangles.

Web Calculator

Why does the integral of 1/x from 0 refuse to give a number?

Because it diverges, and inventing a plausible-looking value would be worse than saying nothing. The result stays an em dash and the page answers Check the function and the limits. Move the bound or split the interval; a double integral needs all four bounds finite for the same reason.

Web Calculator

Why does the solver give 1.414213562 instead of sqrt(2)?

Roots are reported as decimals to ten significant figures, so x^2 - 2 = 0 answers x₁ ≈ 1.414213562 and x₂ ≈ -1.414213562. The working above the answer stays exact - the rounding happens only in the last line, and the page never claims to keep an exact radical.

Web Calculator

Why is my fifth-degree polynomial refused?

The step engine handles a quadratic and a polynomial up to the fourth degree; past that it says Powers above 4 are out of range rather than starting a derivation it cannot finish. For a higher degree, find the roots numerically or look at the curve in the grapher.

Web Calculator

Why does it keep asking me for an equals sign?

Solving needs an equation; a bare expression is a different job. The message says exactly that - use Simplify for something like 3(x+2) - 2(x-1), which gives x + 8, and write 2x + 5 = 11 when you want the derivation of a root.

Web Calculator

Why are there two standard deviations in the results?

They answer different questions. The population one divides by n, the sample one by n-1. For 2, 4, 4, 4, 5, 5, 7, 9 the page gives 2 and 2.13809 - a statistics course usually wants the second, while a plain description of a complete data set wants the first.

Web Calculator

Why does the exponential fit reject my points?

It fits y = a·e^(bx), so every y must be greater than zero and the panel says An exponential fit needs y > 0. The other gates are the ordinary ones: two points minimum for a line, three for a quadratic, and no two rows sharing an x, since a vertical set of points has no function to fit.

Web Calculator

Where do I get the normal distribution on the statistics page?

The standalone statistics page carries two tabs: the one-variable and regression panel, and the distribution app. That keeps a binomial or normal probability next to the data it came from. Inside the workbench the same apps sit behind MODE.

Web Calculator

How large can a matrix be?

In the workbench the matrix editor offers 2x2 and 3x3 and vectors are 2D or 3D, which is where the real devices stop. The standalone matrix page takes larger matrices typed as text, so a 4x4 inverse is available without pretending a handheld does it.

Web Calculator

Why does it say rows have inconsistent column counts?

The parser reads one row per line and requires every row to hold the same number of entries, so 1,2;3,4,5 is a shape error rather than a typo to guess about. An empty row and a cell that isn't a number get their own messages for the same reason: the panel never quietly pads a matrix.

Web Calculator

Why is the cross product limited to three dimensions?

A cross product in the school sense - a vector perpendicular to both inputs - only exists in two and three dimensions, and the device stops at three components. The page answers At most three dimensions instead of silently dropping the fourth.

Web Calculator

Why does -5 come out as FFFB in hexadecimal?

Because base-N mode keeps the value in a 16-bit register, and FFFB is what -5 looks like in two's complement. The row carrying it is labelled as such, so what you are reading is the register contents, not a broken sign.

Web Calculator

Can I convert 0.5 in the base converter?

No. The base-N app is integer-only, and a value with a fraction point is answered with Invalid digits rather than being truncated. Do that arithmetic in the scientific calculator, which keeps the fraction.

Web Calculator

Which bases can it convert between?

Two, eight, ten and sixteen, shown as the four rows HEX, DEC, OCT and BIN of the same register. A deep link can set the base you start from, so a link ending in ?value=FF&from=16 lands with all four rows already filled.

Web Calculator

Is 1 GB the same as 1 GiB here?

No, and the converter keeps the two families apart: 1 GB is 1000 MB while 1 GiB is 1073.741824 MB. That is why a drive size and a memory size can be compared without a silent rounding somewhere in the middle.

Web Calculator

Why doesn't temperature behave like the other units?

It isn't a ratio. Celsius to Fahrenheit multiplies by 9, divides by 5 and adds 32, so it cannot be chained with one factor the way length or mass can. 98.6 F reads 37 C, and 100 C reads 212 F.

Web Calculator

Can I convert currencies with it?

No. The twelve categories are fixed-definition units - length, area, volume, mass, temperature, speed, pressure, energy, power, force, frequency and data. An exchange rate moves every minute and would need a live feed, so we leave it out rather than quote you yesterday's number.

Web Calculator